TICO Product Overview

 

TICO Low Frequency Isolation Material

Where attenuation of vibration is the prime factor, TICO LF / PA pads provide the well-proven scientific answer.  These pads isolate disturbing frequencies where expensive rubber-in-shear or spring devices may have been considered. They are flat and naturally stable under compressive stress, therefore side restraints are rarely needed to ensure a sturdy installation.

TICO LF/PA pads have a bonded-sandwich construction. The centre stratum is synthetic elastomer, precision moulded with a fluted pattern developed for optimum vibration absorption across a specific load range. Top and bottom strata are bonded cork to provide high-friction bearing surfaces. Double layers of TICO LF/PA pads can be used to achieve a lower natural frequency.

TICO CF/PA Pads have been designed for use in critical applications where a low frequency solution is required. TICO CF/PA pads are also available in two different grades, each with its own individual features that can be tailored to meet the needs of the customer. TICO CF/PA pads are complimentary to our TICO LF/PA pads with the additional benefit of complete design flexibility.

 

Typical applications:

  • Heating and ventilation systems with air conditioning units, boiler plant or fans sited near or above inhabited or other critical areas.
  • Heavy compressors, critical areas.
  • Business/computer systems.
  • Precision production plant, test and inspection equipment, sensitive instruments, etc.
  • Room in room isolations,
  • Cinema and theater complexes,
  • Floating floors

 

Typical floating floor installation using TICO bearings

 

Key features:

  • Excellent isolation at low frequencies
  • High lateral stability
  • Isolate structures from plant vibration
  • Isolate equipment from structural disturbance
  • Two grades to suit most applications
  • Rapid installation
  • No mechanical parts to maintain
  • Stock item
  • Should be used in conjunction with TICO adhesives, provides major savings and prevents floor damage

 

Maximum static stress:

TICO LF/PA/10 0.07MN/m2 ( 7,000Kg/m2 )

TICO LF/PA/80 0.7MN/m2 ( 70,000Kg/m2 )

TICO CF/PA/10 0.1 MN/m2 ( 10000 Kg/m2)

TICO CF/PA/80 0.25 MN/m2 ( 25000 Kg/m2)

 

More detailed information can be found in the brochure available as an instant pdf download from this site.

Download NOW

___________________________________________

Information in this document and otherwise supplied to users is based on our general experiences and is given in good faith but, because of particular factors which are outside our knowledge and control and affect the use of products, no warranty is given or implied with respect to such information. Specifications are subject to change without notice. A safe handling data sheet on this material is available as a PDF download.

 